If the pool is an above ground and is considered storable then the following codes apply.
Above ground pool electrical wiring.
All electrical equipment used with storable pools are required to be gfci protected.
With the route planned you can measure for the amount of wire and conduit you need and head to the hardware store or home center.
Connect an 8 gauge wire to the metal posts of the pool the pump and the metal plate on the skimmer and then wire that to the pump to bond the entire pool.
Electrical wiring requirements for swimming pools permanently installed swimming pools are those that are constructed in the ground or partially in the ground and all others capable of holding water with a depth greater than 42 inches 1067 mm 1 pool pump receptacle outlet and wiring method a.
Minimum 8 awg copper wire ground ring must be installed around the pool 4 to 6 below grade 18 to 24 from the pool and connect to the pump motor heater and the pool water bonding.
Yes this is required by the national electrical code.
The motor is to be grounded the pool is to be grounded in four areas with a 8awg bare wire making a circle around the pool.
Also the water is to be bonded.
680 26 b 4 point bonding is not required to the vertical uprights of pools with vinyl liners as it is considered a nonconductive material.
Electrical service wires overhanging a pool spa or hot tub must be at least 22 1 2 feet above the surface of the.
With the main service off to the house wire in gfci circuit breakers to the electrical panel.
Gfci protection most devices and equipment serving pools or spas and the surrounding areas must be protected by ground fault circuit interrupter gfci devices.
On in ground pools there must be at least one gfci protected convenience outlet located between 6 feet and 20 feet from the edge of the pool.
Plug in the pool pump and cover it with a weatherproof cover.
If a pump motor receptacle is located between.
Also is to be inspected by a wire inspector.
Above ground pool circulating pumps.
All this will be tied into your ground of your plug that has to be a twist lock and with a extreme duty cover 5 with a switch disconnect.
Wiring designed to serve a pool pump must be with a green insulated equipment grounding conductor nec article 680 21 a 4 and nec article 680 23 f 2.
Wire the twist lock receptacle.
All 125 volt outlets or receptacles within 2o feet of the inside walls of a pool require gfci protection.
The two 90 degree bends from the ground into the house and shed consume 180 degrees leaving you 180 degrees more for any additional bends.